Some AVRs (for example 1-series) have a different register documentation scheme.
The address of a register is the specified register offset PLUS the peripheral
device address. This way one peripheral can be used multiple times without
defining the same registers multiple times.
Why OUTTGL, not OUT (equivalent to PORTx on ATmega)? The register OUT in the
current version does not even reference the Port I/O peripheral. It is a wrong
reference to another peripheral (writing to OUT currently results in writing
VPORTA.DIR, this is the single-cycle access register to PORTA.DIR, equivalent
to DDRA on ATmega). When comparing this might be confusing, i would recommend
using PORTx.OUTTGL as example.
The offset of register OUTTGL in the PORT peripheral is 0x7 (see page 140), but
the address of PORTA.OUTTGL is not 0x7, instead it is 0x407. The actual address
is the peripheral address of PORTA (defined in the peripheral address map, see
page 45) plus the register offset defined in the register description.
A quick look to the current definition clarifies the problem: The peripheral
address isn't taken into account. Multiple registers share the same address (all
registers whose offset inside the peripheral is 0x7) and OUTTGL isn't assigned
to any specific port.
// https://github.com/avr-rust/avrd/blob/master/src/gen/attiny212.rs
.../// Application Code Section End.pubconstAPPEND:*mutu8 = 0x7as*mutu8;/// LUT Control 0 C.pubconstLUT0CTRLC:*mutu8 = 0x7as*mutu8;/// User Row Byte 7.pubconstUSERROW7:*mutu8 = 0x7as*mutu8;/// Control F Set.pubconstCTRLFSET:*mutu8 = 0x7as*mutu8;/// Serial Number Byte 4.pubconstSERNUM4:*mutu8 = 0x7as*mutu8;/// Control C.pubconstCTRLC:*mutu8 = 0x7as*mutu8;/// Master Address.pubconstMADDR:*mutu8 = 0x7as*mutu8;/// Clock Select.pubconstCLKSEL:*mutu8 = 0x7as*mutu8;/// Output Value Toggle.pubconstOUTTGL:*mutu8 = 0x7as*mutu8;
...
Instead, the definition of PORTA has to look like this:
PS: Attiny 0-series (202,204,402,404,...) could also be supported by this lib,
as they are binary compatible. Microchip says: "Register names, bit names, and
bit group names can be expected to be the same for both families, when present."
(https://ww1.microchip.com/downloads/en/Appnotes/Migration-Between-tinyAVR-1-and-0-series-00002636B.pdf).
When using only peripheral modules present on all devices, one program can be
used on all 0- and 1-series devices without recompiling(!).
Currently 0-series devices are supported (if there weren't this bug) by
replacing the 0 in the part name with 1 and making sure, that only existent
peripheral modules are used.
The text was updated successfully, but these errors were encountered:
Some AVRs (for example 1-series) have a different register documentation scheme.
The address of a register is the specified register offset PLUS the peripheral
device address. This way one peripheral can be used multiple times without
defining the same registers multiple times.
Example ATiny 1-series: PORTA.OUTTGL
Datasheet:
https://ww1.microchip.com/downloads/en/DeviceDoc/ATtiny212-214-412-414-416-DataSheet-DS40002287A.pdf
The offset of register OUTTGL in the PORT peripheral is 0x7 (see page 140), but
the address of PORTA.OUTTGL is not 0x7, instead it is 0x407. The actual address
is the peripheral address of PORTA (defined in the peripheral address map, see
page 45) plus the register offset defined in the register description.
A quick look to the current definition clarifies the problem: The peripheral
address isn't taken into account. Multiple registers share the same address (all
registers whose offset inside the peripheral is 0x7) and OUTTGL isn't assigned
to any specific port.
Instead, the definition of PORTA has to look like this:
PS: Attiny 0-series (202,204,402,404,...) could also be supported by this lib,
as they are binary compatible. Microchip says: "Register names, bit names, and
bit group names can be expected to be the same for both families, when present."
(https://ww1.microchip.com/downloads/en/Appnotes/Migration-Between-tinyAVR-1-and-0-series-00002636B.pdf).
When using only peripheral modules present on all devices, one program can be
used on all 0- and 1-series devices without recompiling(!).
Currently 0-series devices are supported (if there weren't this bug) by
replacing the 0 in the part name with 1 and making sure, that only existent
peripheral modules are used.