Notifications
You must be signed in to change notification settings - Fork 10
/
alarmrx.py
executable file
·872 lines (787 loc) · 41.2 KB
/
alarmrx.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
#!/usr/bin/env python3
#
# Texecom Alarm Receiving Server
# Copyright 2016-2020 Mike Stirling
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
#
import socketserver
import configparser
import logging
import sys
import daemon
import lockfile
import json
import paho.mqtt.client as mqtt
import time
from datetime import datetime, timedelta
from threading import Thread, Lock
from binascii import hexlify
from functools import reduce
APP_NAME = 'alarmserver'
CONFIG_FILE = '/etc/alarmserver/alarmserver.conf'
# Configuration defaults
DEFAULTS = {
'server' : {
'host' : '0.0.0.0',
'port' : 10500,
'log_file' : '/tmp/alarmserver.log',
'pid_file' : '/tmp/alarmserver.pid',
},
'alarm' : {
'polling_interval' : 2,
'max_misses' : 1,
'account_file' : '/etc/alarmserver/accounts.conf'
},
'mqtt' : {
'host' : '127.0.0.1',
'port' : 1883,
'username' : None,
'password' : None,
'cafile' : None
},
}
config = configparser.ConfigParser()
config.read(CONFIG_FILE)
def get_config(section, option):
try:
value = config.get(section, option)
except (configparser.NoOptionError, configparser.NoSectionError):
value = DEFAULTS[section][option]
return value
LOG_FILE = get_config('server', 'log_file')
PID_FILE = get_config('server', 'pid_file')
# Configure logging
LOG_FORMAT = '%(asctime)-15s %(levelname)-6s %(tag)-15s %(message)s'
logging.basicConfig(level=logging.DEBUG, format = LOG_FORMAT)
logger = logging.getLogger(APP_NAME)
fh = logging.FileHandler(LOG_FILE, 'a')
fh.setLevel(logging.DEBUG)
fh.setFormatter(logging.Formatter(LOG_FORMAT))
logger.addHandler(fh)
class AccountManager(object):
error = lambda self, acc, msg: logger.error(msg, extra={'tag': acc})
info = lambda self, acc, msg: logger.info(msg, extra={'tag': acc})
debug = lambda self, acc, msg: logger.debug(msg, extra={'tag': acc})
# Polling timer tolerance (seconds)
POLLING_TOLERANCE = 30
def __init__(self):
self.MAX_MISSES = int(get_config('alarm', 'max_misses'))
self.ACCOUNT_FILENAME = get_config('alarm', 'account_file')
self.POLLING_INTERVAL = int(get_config('alarm', 'polling_interval'))
self.account_lock = Lock()
self.watchdog_running = False
self.polling_timeout = timedelta(minutes=self.POLLING_INTERVAL, seconds=self.POLLING_TOLERANCE)
# Open and load list of accounts
# File should be formatted as <account number> <expected IP address>
self.accounts = {}
try:
with open(self.ACCOUNT_FILENAME) as f:
while True:
entry = f.readline().strip()
if not entry:
break
if entry[0] == '#':
continue
fields = entry.split()
if len(fields) < 2:
# Skip if row has less than 2 columns
continue
(account, ip) = fields[:2]
self.accounts[account] = dict(ip=ip, last_poll=None, timeout=None, missed=0)
except IOError:
# Missing account file just means no accounts
self.error('', 'Failed to open account file')
def publish_polling_event(self, account, state):
# Post event message to broker (not retained)
info = {
'client_ip': '',
'client_port': 0,
'account': int(account),
'timestamp': datetime.now().isoformat(),
'area': 0,
'value': 0,
'value_type': '',
'extra_text': '',
}
if state:
info['event'] = 'Polling restored'
msg = 'Polling restored'
else:
info['event'] = 'Polling timeout'
msg = 'Polling timeout'
self.mqtt_client.publish("alarms/%s/event" % (account), json.dumps(info), qos=1, retain=False)
self.mqtt_client.publish("alarms/%s/message" % (account), msg, qos=1, retain=False)
def start_polling_watchdog(self):
# Initialise polling timeouts
for k,acc in self.accounts.items():
acc['timeout'] = datetime.now() + self.polling_timeout
# Start timer for polling monitor
self.watchdog_running = True
self.watchdog_thread = Thread(target = self.watchdog_func)
self.watchdog_thread.daemon = True
self.watchdog_thread.start()
def stop_polling_watchdog(self):
self.watchdog_running = False
self.watchdog_thread.join()
def watchdog_func(self):
while self.watchdog_running:
self.account_lock.acquire()
# Check for missed polls every few seconds. Doesn't really
# matter if we are a few seconds late
now = datetime.now()
for k,acc in self.accounts.items():
if acc['timeout'] < now:
# Account has missed a poll event
acc['missed'] = acc['missed'] + 1
acc['timeout'] = now + self.polling_timeout
self.info(k, "Polling deadline missed (%d/%d)" % (acc['missed'], self.MAX_MISSES))
if acc['missed'] == self.MAX_MISSES:
# Generate polling error event
self.error(k, "Polling alert")
self.publish_polling_event(k, False)
self.account_lock.release()
time.sleep(5)
def polled(self, account):
self.account_lock.acquire()
try:
self.info(account, 'Poll received')
acc = self.accounts[account]
if acc['missed'] > 0:
# Generate polling restored event
self.info(account, "Polling recovered after %d misses" % (acc['missed']))
self.publish_polling_event(account, True)
now = datetime.now()
acc['last_poll'] = now
acc['timeout'] = now + self.polling_timeout
acc['missed'] = 0
except KeyError:
self.error(account, 'Unknown account')
self.account_lock.release()
def get_ip(self, account):
try:
return self.accounts[account]['ip']
except KeyError:
self.error(account, 'Unknown account')
return None
def get_polling_interval(self, account):
return self.POLLING_INTERVAL
class EventParser(object):
error = lambda self, msg: logger.error(type(self).__name__ + ': ' + msg, extra={'tag': self.client_ip})
info = lambda self, msg: logger.info(type(self).__name__ + ': ' + msg, extra={'tag': self.client_ip})
debug = lambda self, msg: logger.debug(type(self).__name__ + ': ' + msg, extra={'tag': self.client_ip})
# Defaults
client_ip = '0.0.0.0'
account_number = ''
area = 0
event = ''
description = ''
value = 0
value_name = ''
extra_text = ''
def __init__(self):
pass
class ContactId(EventParser):
QUALIFIERS = {
1 : 'Event/Activated',
3 : 'Restore/Secured',
6 : 'Status'
}
EVENTS = {
100: 'Medical',
110: 'Fire',
120: 'Panic',
121: 'Duress',
122: 'Silent Attack',
123: 'Audible Attack',
130: 'Intruder',
131: 'Perimeter',
132: 'Interior',
133: '24 Hour',
134: 'Entry/Exit',
135: 'Day/Night',
136: 'Outdoor',
137: 'Zone Tamper',
139: 'Confirmed Alarm',
145: 'System Tamper',
300: 'System Trouble',
301: 'AC Lost',
302: 'Low Battery',
305: 'System Power Up',
320: 'Mains Over-voltage',
333: 'Network Failure',
351: 'ATS Path Fault',
354: 'Failed to Communicate',
400: 'Arm/Disarm',
401: 'Arm/Disarm by User',
403: 'Automatic Arm/Disarm',
406: 'Alarm Abort',
407: 'Remote Arm/Disarm',
408: 'Quick Arm',
411: 'Download Start',
412: 'Download End',
441: 'Part Arm',
457: 'Exit Error',
459: 'Recent Closing',
570: 'Zone Locked Out',
601: 'Manual Test',
602: 'Periodic Test',
607: 'User Walk Test',
623: 'Log Capacity Alert',
625: 'Date/Time Changed',
627: 'Program Mode Entry',
628: 'Program Mode Exit',
}
def __init__(self, client_ip, msg):
self.client_ip = client_ip
# Validate
if len(msg) != 16:
self.error("Invalid message size %u" % (len(msg)))
return
if msg[4:6] != b'18' and msg[4:6] != b'98':
self.error("Invalid message type %s" % (msg[4:6]))
return
# Parse fields
account = msg[0:4].decode('ascii').replace('A','0')
try:
qualifier = int(msg[6:7])
event = int(msg[7:10])
group = int(msg[10:12])
value = int(msg[12:15])
except ValueError:
self.error("Parse error")
return
try:
qualstr = ' ' + self.QUALIFIERS[qualifier]
except KeyError:
qualstr = ''
try:
eventstr = self.EVENTS[event]
except KeyError:
eventstr = "Unknown Event %03u" % (event)
# Populate class properties
self.account_number = account
self.area = group
self.event = eventstr + qualstr
self.description = eventstr + qualstr
self.value = value
self.value_name = 'Zone/User'
class SIA(EventParser):
EVENTS = {
'AA': ("Alarm - Panel Substitution", "An attempt to substitute an alternate alarm panel for a secure panel has been made", "Condition Number"),
'AB': ("Abort", "An event message was not sent due to User action", "Zone"),
'AN': ("Analog Restoral", "An analog fire sensor has been restored to normal operation", "Zone"),
'AR': ("AC Restoral", "AC power has been restored", ""),
'AS': ("Analog Service", "An analog fire sensor needs to be cleaned or calibrated", "Zone"),
'AT': ("AC Trouble", "AC power has been failed", ""),
'BA': ("Burglary Alarm", "Burglary zone has been violated while armed", "Zone"),
'BB': ("Burglary Bypass", "Burglary zone has been bypassed", "Zone"),
'BC': ("Burglary Cancel", "Alarm has been cancelled by authorized user", "User"),
'BD': ("Swinger Trouble", "A non-fire zone has been violated after a Swinger Shutdown on the zone", "Zone"),
'BE': ("Swinger Trouble Restore", "A non-fire zone restores to normal from a Swinger Trouble state", "Zone"),
'BG': ("Unverified Event - Burglary", "A point assigned to a Cross Point group has gone into alarm but the Cross Point remained normal", "Zone"),
'BH': ("Burglary Alarm Restore", "Alarm condition eliminated", "Zone"),
'BJ': ("Burglary Trouble Restore", "Trouble condition eliminated", "Zone"),
'BM': ("Burglary Alarm - Cross Point", "Burglary alarm w/cross point also in alarm - alarm verified", "Zone"),
'BR': ("Burglary Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'BS': ("Burglary Supervisory", "Unsafe intrusion detection system condition", "Zone"),
'BT': ("Burglary Trouble", "Burglary zone disabled by fault", "Zone"),
'BU': ("Burglary Unbypass", "Zone bypass has been removed", "Zone"),
'BV': ("Burglary Verified", "A burglary alarm has occurred and been verified within programmed conditions. (zone or point not sent)", "Area"),
'BX': ("Burglary Test", "Burglary zone activated during testing", "Zone"),
'BZ': ("Missing Supervision", "A non-fire Supervisory point has gone missing", "Zone"),
'CA': ("Automatic Closing", "System armed automatically", "Area"),
'CD': ("Closing Delinquent", "The system has not been armed for a programmed amount of time", "Area"),
'CE': ("Closing Extend", "Extend closing time", "User"),
'CF': ("Forced Closing", "System armed, some zones not ready", "User"),
'CG': ("Close Area", "System has been partially armed", "Area"),
'CI': ("Fail to Close", "An area has not been armed at the end of the closing window", "Area"),
'CJ': ("Late Close", "An area was armed after the closing window", "User"),
'CK': ("Early Close", "An area was armed before the closing window", "User"),
'CL': ("Closing Report", "System armed, normal", "User"),
'CM': ("Missing Alarm - Recent Closing", "A point has gone missing within 2 minutes of closing", "Zone"),
'CO': ("Command Sent", "A command has been sent to an expansion/peripheral device", "Condition Number"),
'CP': ("Automatic Closing", "System armed automatically", "User"),
'CQ': ("Remote Closing", "The system was armed from a remote location", "User"),
'CR': ("Recent Closing", "An alarm occurred within five minutes after the system was closed", "User"),
'CS': ("Closing Keyswitch", "Account has been armed by keyswitch", "Zone"),
'CT': ("Late to Open", "System was not disarmed on time", "Area"),
'CW': ("Was Force Armed", "Header for a force armed session, forced point msgs may follow", "Area"),
'CX': ("Custom Function Executed", "The panel has executed a preprogrammed set of instructions", "Custom Function"),
'CZ': ("Point Closing", "A point, as opposed to a whole area or account, has closed", "Zone"),
'DA': ("Card Assigned", "An access ID has been added to the controller", "User"),
'DB': ("Card Deleted", "An access ID has been deleted from the controller", "User"),
'DC': ("Access Closed", "Access to all users prohibited", "Door"),
'DD': ("Access Denied", "Access denied, unknown code", "Door"),
'DE': ("Request to Enter", "An access point was opened via a Request to Enter device", "Door"),
'DF': ("Door Forced", "Door opened without access request", "Door"),
'DG': ("Access Granted", "Door access granted", "Door"),
'DH': ("Door Left Open - Restoral", "An access point in a Door Left Open state has restored", "Door"),
'DI': ("Access Denied - Passback", "Access denied because credential has not exited area before attempting to re-enter same area", "Door"),
'DJ': ("Door Forced - Trouble", "An access point has been forced open in an unarmed area", "Door"),
'DK': ("Access Lockout", "Access denied, known code", "Door"),
'DL': ("Door Left Open - Alarm", "An open access point when open time expired in an armed area", "Door"),
'DM': ("Door Left Open - Trouble", "An open access point when open time expired in an unarmed area", "Door"),
'DN': ("Door Left Open (non-alarm, non-trouble)", "An access point was open when the door cycle time expired", "Door"),
'DO': ("Access Open", "Access to authorized users allowed", "Door"),
'DP': ("Access Denied - Unauthorized Time", "An access request was denied because the request is occurring outside the user's authorized time window(s)", "Door"),
'DQ': ("Access Denied Unauthorized Arming State", "An access request was denied because the user was not authorized in this area when the area was armed", "Door"),
'DR': ("Door Restoral", "Access alarm/trouble condition eliminated", "Door"),
'DS': ("Door Station", "Identifies door for next report", "Door"),
'DT': ("Access Trouble", "Access system trouble", ""),
'DU': ("Dealer ID", "Dealer ID number", "Dealer ID"),
'DV': ("Access Denied Unauthorized Entry Level", "An access request was denied because the user is not authorized in this area", "Door"),
'DW': ("Access Denied - Interlock", "An access request was denied because the doors associated Interlock point is open", "Door"),
'DX': ("Request to Exit", "An access point was opened via a Request to Exit device", "Door"),
'DY': ("Door Locked", "The door's lock has been engaged", "Door"),
'DZ': ("Access Denied - Door Secured", "An access request was denied because the door has been placed in an Access Closed state", "Door"),
'EA': ("Exit Alarm", "An exit zone remained violated at the end of the exit delay period", "Zone"),
'EE': ("Exit Error", "An exit zone remained violated at the end of the exit delay period", "User"),
'EJ': ("Expansion Tamper Restore", "Expansion device tamper restoral", "Device"),
'EM': ("Expansion Device Missing", "Expansion device missing", "Device"),
'EN': ("Expansion Missing Restore", "Expansion device communications re-established", "Device"),
'ER': ("Expansion Restoral", "Expansion device trouble eliminated", "Expander"),
'ES': ("Expansion Device Tamper", "Expansion device enclosure tamper", "Device"),
'ET': ("Expansion Trouble", "Expansion device trouble", "Expander"),
'EX': ("External Device Condition", "A specific reportable condition is detected on an external device", "Device"),
'EZ': ("Missing Alarm - Exit Error", "A point remained missing at the end of the exit delay period", "Zone"),
'FA': ("Fire Alarm", "Fire condition detected", "Zone"),
'FB': ("Fire Bypass", "Zone has been bypassed", "Zone"),
'FC': ("Fire Cancel", "A Fire Alarm has been cancelled by an authorized person", "Zone"),
'FG': ("Unverified Event - Fire", "A point assigned to a Cross Point group has gone into alarm but the Cross Point remained normal", "Zone"),
'FH': ("Fire Alarm Restore", "Alarm condition eliminated", "Zone"),
'FI': ("Fire Test Begin", "The transmitter area's fire test has begun", "Area"),
'FJ': ("Fire Trouble Restore", "Trouble condition eliminated", "Zone"),
'FK': ("Fire Test End", "The transmitter area's fire test has ended", "Area"),
'FL': ("Fire Alarm Silenced", "The fire panel's sounder was silenced by command", "Zone"),
'FM': ("Fire Alarm - Cross Point", "Fire Alarm with Cross Point also in alarm verifying the Fire Alarm", "Zone"),
'FQ': ("Fire Supervisory Trouble Restore", "A fire supervisory zone that was in trouble condition has now restored to normal", "Zone"),
'FR': ("Fire Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'FS': ("Fire Supervisory", "Unsafe fire detection system condition", "Zone"),
'FT': ("Fire Trouble", "Zone disabled by fault", "Zone"),
'FU': ("Fire Unbypass", "Bypass has been removed", "Zone"),
'FV': ("Fire Supervision Restore", "A fire supervision zone that was in alarm has restored to normal", "Zone"),
'FW': ("Fire Supervisory Trouble", "A fire supervisory zone is now in a trouble condition", "Zone"),
'FX': ("Fire Test", "Fire zone activated during test", "Zone"),
'FY': ("Missing Fire Trouble", "A fire point is now logically missing", "Zone"),
'FZ': ("Missing Fire Supervision", "A Fire Supervisory point has gone missing", "Zone"),
'GA': ("Gas Alarm", "Gas alarm condition detected", "Zone"),
'GB': ("Gas Bypass", "Zone has been bypassed", "Zone"),
'GH': ("Gas Alarm Restore", "Alarm condition eliminated", "Zone"),
'GJ': ("Gas Trouble Restore", "Trouble condition eliminated", "Zone"),
'GR': ("Gas Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'GS': ("Gas Supervisory", "Unsafe gas detection system condition", "Zone"),
'GT': ("Gas Trouble", "Zone disabled by fault", "Zone"),
'GU': ("Gas Unbypass", "Bypass has been removed", "Zone"),
'GX': ("Gas Test", "Zone activated during test", "Zone"),
'HA': ("Holdup Alarm", "Silent alarm, user under duress", "Zone"),
'HB': ("Holdup Bypass", "Zone has been bypassed", "Zone"),
'HH': ("Holdup Alarm Restore", "Alarm condition eliminated", "Zone"),
'HJ': ("Holdup Trouble Restore", "Trouble condition eliminated", "Zone"),
'HR': ("Holdup Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'HS': ("Holdup Supervisory", "Unsafe holdup system condition", "Zone"),
'HT': ("Holdup Trouble", "Zone disabled by fault", "Zone"),
'HU': ("Holdup Unbypass", "Bypass has been removed", "Zone"),
'IA': ("Equipment Failure Condition", "A specific, reportable condition is detected on a device", "Zone"),
'IR': ("Equipment Fail - Restoral", "The equipment condition has been restored to normal", "Zone"),
'JA': ("User Code Tamper", "Too many unsuccessful attempts have been made to enter a user ID", "Area"),
'JD': ("Date Changed", "The date was changed in the transmitter/receiver", "User"),
'JH': ("Holiday Changed", "The transmitter's holiday schedule has been changed", "User"),
'JK': ("Latchkey Alert", "A designated user passcode has not been entered during a scheduled time window", "User"),
'JL': ("Log Threshold", "The transmitter's log memory has reached its threshold level", ""),
'JO': ("Log Overflow", "The transmitter's log memory has overflowed", ""),
'JP': ("User On Premises", "A designated user passcode has been used to gain access to the premises.", "User"),
'JR': ("Schedule Executed", "An automatic scheduled event was executed", "Area"),
'JS': ("Schedule Changed", "An automatic schedule was changed", "User"),
'JT': ("Time Changed", "The time was changed in the transmitter/receiver", "User"),
'JV': ("User Code Changed", "A user's code has been changed", "User"),
'JX': ("User Code Deleted", "A user's code has been removed", "User"),
'JY': ("User Code Added", "A user's code has been added", "User"),
'JZ': ("User Level Set", "A user's authority level has been set", "User"),
'KA': ("Heat Alarm", "High temperature detected on premise", "Zone"),
'KB': ("Heat Bypass", "Zone has been bypassed", "Zone"),
'KH': ("Heat Alarm Restore", "Alarm condition eliminated", "Zone"),
'KJ': ("Heat Trouble Restore", "Trouble condition eliminated", "Zone"),
'KR': ("Heat Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'KS': ("Heat Supervisory", "Unsafe heat detection system condition", "Zone"),
'KT': ("Heat Trouble", "Zone disabled by fault", "Zone"),
'KU': ("Heat Unbypass", "Bypass has been removed", "Zone"),
'LB': ("Local Program", "Begin local programming", ""),
'LD': ("Local Program Denied", "Access code incorrect", ""),
'LE': ("Listen-in Ended", "The listen-in session has been terminated", ""),
'LF': ("Listen-in Begin", "The listen-in session with the RECEIVER has begun", ""),
'LR': ("Phone Line Restoral", "Phone line restored to service", "Line"),
'LS': ("Local Program Success", "Local programming successful", ""),
'LT': ("Phone Line Trouble", "Phone line trouble report", "Line"),
'LU': ("Local Program Fail", "Local programming unsuccessful", ""),
'LX': ("Local Programming Ended", "A local programming session has been terminated", ""),
'MA': ("Medical Alarm", "Emergency assistance request", "Zone"),
'MB': ("Medical Bypass", "Zone has been bypassed", "Zone"),
'MH': ("Medical Alarm Restore", "Alarm condition eliminated", "Zone"),
'MI': ("Message", "A canned message is being sent", "Message"),
'MJ': ("Medical Trouble Restore", "Trouble condition eliminated", "Zone"),
'MR': ("Medical Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'MS': ("Medical Supervisory", "Unsafe system condition exists", "Zone"),
'MT': ("Medical Trouble", "Zone disabled by fault", "Zone"),
'MU': ("Medical Unbypass", "Bypass has been removed", "Zone"),
'NA': ("No Activity", "There has been no zone activity for a programmed amount of time", "Zone"),
'NC': ("Network Condition", "A communications network has a specific reportable condition", "Network"),
'NF': ("Forced Perimeter Arm", "Some zones/points not ready", "Area"),
'NL': ("Perimeter Armed", "An area has been perimeter armed", "Area"),
'NM': ("Perimeter Armed, User Defined", "A user defined area has been perimeter armed", "Area"),
'NR': ("Network Restoral", "A communications network has returned to normal operation", "Network"),
'NS': ("Activity Resumed", "A zone has detected activity after an alert", "Zone"),
'NT': ("Network Failure", "A communications network has failed", "Network"),
'OA': ("Automatic Opening", "System has disarmed automatically", "Area"),
'OC': ("Cancel Report", "Untyped zone cancel", "User"),
'OG': ("Open Area", "System has been partially disarmed", "Area"),
'OH': ("Early to Open from Alarm", "An area in alarm was disarmed before the opening window", "User"),
'OI': ("Fail to Open", "An area has not been armed at the end of the opening window", "Area"),
'OJ': ("Late Open", "An area was disarmed after the opening window", "User"),
'OK': ("Early Open", "An area was disarmed before the opening window", "User"),
'OL': ("Late to Open from Alarm", "An area in alarm was disarmed after the opening window", "User"),
'OP': ("Opening Report", "Account was disarmed", "User"),
'OQ': ("Remote Opening", "The system was disarmed from a remote location", "User"),
'OR': ("Disarm From Alarm", "Account in alarm was reset/disarmed", "User"),
'OS': ("Opening Keyswitch", "Account has been disarmed by keyswitch", "Zone"),
'OT': ("Late To Close", "System was not armed on time", "User"),
'OU': ("Output State - Trouble", "An output on a peripheral device or NAC is not functioning", "Output"),
'OV': ("Output State - Restore", "An output on a peripheral device or NAC is back to normal operation", "Output"),
'OZ': ("Point Opening", "A point, rather than a full area or account, disarmed", "Zone"),
'PA': ("Panic Alarm", "Emergency assistance request, manually activated", "Zone"),
'PB': ("Panic Bypass", "Panic zone has been bypassed", "Zone"),
'PH': ("Panic Alarm Restore", "Alarm condition eliminated", "Zone"),
'PJ': ("Panic Trouble Restore", "Trouble condition eliminated", "Zone"),
'PR': ("Panic Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'PS': ("Panic Supervisory", "Unsafe system condition exists", "Zone"),
'PT': ("Panic Trouble", "Zone disabled by fault", "Zone"),
'PU': ("Panic Unbypass", "Panic zone bypass has been removed", "Zone"),
'QA': ("Emergency Alarm", "Emergency assistance request", "Zone"),
'QB': ("Emergency Bypass", "Zone has been bypassed", "Zone"),
'QH': ("Emergency Alarm Restore", "Alarm condition has been eliminated", "Zone"),
'QJ': ("Emergency Trouble Restore", "Trouble condition has been eliminated", "Zone"),
'QR': ("Emergency Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'QS': ("Emergency Supervisory", "Unsafe system condition exists", "Zone"),
'QT': ("Emergency Trouble", "Zone disabled by fault", "Zone"),
'QU': ("Emergency Unbypass", "Bypass has been removed", "Zone"),
'RA': ("Remote Programmer Call Failed", "Transmitter failed to communicate with the remote programmer", ""),
'RB': ("Remote Program Begin", "Remote programming session initiated", ""),
'RC': ("Relay Close", "A relay has energized", "Relay"),
'RD': ("Remote Program Denied", "Access passcode incorrect", ""),
'RN': ("Remote Reset", "A TRANSMITTER was reset via a remote programmer", ""),
'RO': ("Relay Open", "A relay has de-energized", "Relay"),
'RP': ("Automatic Test", "Automatic communication test report", ""),
'RR': ("Power Up", "System lost power, is now restored", ""),
'RS': ("Remote Program Success", "Remote programming successful", ""),
'RT': ("Data Lost", "Dialer data lost, transmission error", "Line"),
'RU': ("Remote Program Fail", "Remote programming unsuccessful", ""),
'RX': ("Manual Test", "Manual communication test report", "User"),
'RY': ("Test Off Normal", "Test signal(s) indicates abnormal condition(s) exist", "Zone"),
'SA': ("Sprinkler Alarm", "Sprinkler flow condition exists", "Zone"),
'SB': ("Sprinkler Bypass", "Sprinkler zone has been bypassed", "Zone"),
'SC': ("Change of State", "An expansion/peripheral device is reporting a new condition or state change", "Condition Number"),
'SH': ("Sprinkler Alarm Restore", "Alarm condition eliminated", "Zone"),
'SJ': ("Sprinkler Trouble Restore", "Trouble condition eliminated", "Zone"),
'SR': ("Sprinkler Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'SS': ("Sprinkler Supervisory", "Unsafe sprinkler system condition", "Zone"),
'ST': ("Sprinkler Trouble", "Zone disabled by fault", "Zone"),
'SU': ("Sprinkler Unbypass", "Sprinkler zone bypass has been removed", "Zone"),
'TA': ("Tamper Alarm", "Alarm equipment enclosure opened", "Zone"),
'TB': ("Tamper Bypass", "Tamper detection has been bypassed", "Zone"),
'TC': ("All Points Tested", "All point tested", ""),
'TE': ("Test End", "Communicator restored to operation", ""),
'TH': ("Tamper Alarm Restore", "An Expansion Device's tamper switch restores to normal from an Alarm state", ""),
'TJ': ("Tamper Trouble Restore", "An Expansion Device's tamper switch restores to normal from a Trouble state", ""),
'TP': ("Walk Test Point", "This point was tested during a Walk Test", "Zone"),
'TR': ("Tamper Restoral", "Alarm equipment enclosure has been closed", "Zone"),
'TS': ("Test Start", "Communicator taken out of operation", ""),
'TT': ("Tamper Trouble", "Equipment enclosure opened in disarmed state", "Zone"),
'TU': ("Tamper Unbypass", "Tamper detection bypass has been removed", "Zone"),
'TW': ("Area Watch Start", "Area watch feature has been activated", ""),
'TX': ("Test Report", "An unspecified (manual or automatic) communicator test", ""),
'TZ': ("Area Watch End", "Area watch feature has been deactivated", ""),
'UA': ("Untyped Zone Alarm", "Alarm condition from zone of unknown type", "Zone"),
'UB': ("Untyped Zone Bypass", "Zone of unknown type has been bypassed", "Zone"),
'UG': ("Unverified Event - Untyped", "A point assigned to a Cross Point group has gone into alarm but the Cross Point remained normal", "Zone"),
'UH': ("Untyped Alarm Restore", "Alarm condition eliminated", "Zone"),
'UJ': ("Untyped Trouble Restore", "Trouble condition eliminated", "Zone"),
'UR': ("Untyped Zone Restoral", "Alarm/trouble condition eliminated from zone of unknown type", "Zone"),
'US': ("Untyped Zone Supervisory", "Unsafe condition from zone of unknown type", "Zone"),
'UT': ("Untyped Zone Trouble", "Trouble condition from zone of unknown type", "Zone"),
'UU': ("Untyped Zone Unbypass", "Bypass on zone of unknown type has been removed", "Zone"),
'UX': ("Undefined", "An undefined alarm condition has occurred", ""),
'UY': ("Untyped Missing Trouble", "A point or device which was not armed is now logically missing", "Zone"),
'UZ': ("Untyped Missing Alarm", "A point or device which was armed is now logically missing", "Zone"),
'VI': ("Printer Paper In", "TRANSMITTER or RECEIVER paper in", "Printer"),
'VO': ("Printer Paper Out", "TRANSMITTER or RECEIVER paper out", "Printer"),
'VR': ("Printer Restore", "TRANSMITTER or RECEIVER trouble restored", "Printer"),
'VT': ("Printer Trouble", "TRANSMITTER or RECEIVER trouble", "Printer"),
'VX': ("Printer Test", "TRANSMITTER or RECEIVER test", "Printer"),
'VY': ("Printer Online", "RECEIVER'S printer is now online", ""),
'VZ': ("Printer Offline", "RECEIVER'S printer is now offline", ""),
'WA': ("Water Alarm", "Water detected at protected premises", "Zone"),
'WB': ("Water Bypass", "Water detection has been bypassed", "Zone"),
'WH': ("Water Alarm Restore", "Water alarm condition eliminated", "Zone"),
'WJ': ("Water Trouble Restore", "Water trouble condition eliminated", "Zone"),
'WR': ("Water Restoral", "Water alarm/trouble condition has been eliminated", "Zone"),
'WS': ("Water Supervisory", "Water unsafe water detection system condition", "Zone"),
'WT': ("Water Trouble", "Water zone disabled by fault", "Zone"),
'WU': ("Water Unbypass", "Water detection bypass has been removed", "Zone"),
'XA': ("Extra Account Report", "CS RECEIVER has received an event from a non-existent account", ""),
'XE': ("Extra Point", "Panel has sensed an extra point not specified for this site", "Zone"),
'XF': ("Extra RF Point", "Panel has sensed an extra RF point not specified for this site", "Zone"),
'XH': ("RF Interference Restoral", "A radio device is no longer detecting RF Interference", "Receiver"),
'XI': ("Sensor Reset", "A user has reset a sensor", "Zone"),
'XJ': ("RF Receiver Tamper Restoral", "A Tamper condition at a premises RF Receiver has been restored", "Receiver"),
'XL': ("Low Received Signal Strength", "The RF signal strength of a reported event is below minimum level", "Receiver"),
'XM': ("Missing Alarm - Cross Point", "Missing Alarm verified by Cross Point in Alarm (or missing)", "Zone"),
'XQ': ("RF Interference", "A radio device is detecting RF Interference", "Receiver"),
'XR': ("Transmitter Battery Restoral", "Low battery has been corrected", "Zone"),
'XS': ("RF Receiver Tamper", "A Tamper condition at a premises receiver is detected", "Receiver"),
'XT': ("Transmitter Battery Trouble", "Low battery in wireless transmitter", "Zone"),
'XW': ("Forced Point", "A point was forced out of the system at arm time", "Zone"),
'XX': ("Fail to Test", "A specific test from a panel was not received", ""),
'YA': ("Bell Fault", "A trouble condition has been detected on a Local Bell, Siren, or Annunciator", ""),
'YB': ("Busy Seconds", "Percent of time receiver's line card is on-line", "Line Card"),
'YC': ("Communications Fail", "RECEIVER and TRANSMITTER", ""),
'YD': ("Receiver Line Card Trouble", "A line card identified by the passed address is in trouble", "Line Card"),
'YE': ("Receiver Line Card Restored", "A line card identified by the passed address is restored", "Line Card"),
'YF': ("Parameter Checksum Fail", "System data corrupted", ""),
'YG': ("Parameter Changed", "A TRANSMITTER'S parameters have been changed", ""),
'YH': ("Bell Restored", "A trouble condition has been restored on a Local Bell, Siren, or Annunciator", ""),
'YI': ("Overcurrent Trouble", "An Expansion Device has detected an overcurrent condition", ""),
'YJ': ("Overcurrent Restore", "An Expansion Device has restored from an overcurrent condition", ""),
'YK': ("Communications Restoral", "TRANSMITTER has resumed communication with a RECEIVER", ""),
'YM': ("System Battery Missing", "TRANSMITTER/RECEIVER battery is missing", ""),
'YN': ("Invalid Report", "TRANSMITTER has sent a packet with invalid data", ""),
'YO': ("Unknown Message", "An unknown message was received from automation or the printer", ""),
'YP': ("Power Supply Trouble", "TRANSMITTER/RECEIVER has a problem with the power supply", ""),
'YQ': ("Power Supply Restored", "TRANSMITTER'S/RECEIVER'S power supply has been restored", ""),
'YR': ("System Battery Restoral", "Low battery has been corrected", ""),
'YS': ("Communications Trouble", "RECEIVER and TRANSMITTER", ""),
'YT': ("System Battery Trouble", "Low battery in control/communicator", ""),
'YU': ("Diagnostic Error", "An expansion/peripheral device is reporting a diagnostic error", "Condition Number"),
'YW': ("Watchdog Reset", "The TRANSMITTER created an internal reset", ""),
'YX': ("Service Required", "A TRANSMITTER/RECEIVER needs service", ""),
'YY': ("Status Report", "This is a header for an account status report transmission", ""),
'YZ': ("Service Completed", "Required TRANSMITTER / RECEIVER service completed", ""),
'ZA': ("Freeze Alarm", "Low temperature detected at premises", "Zone"),
'ZB': ("Freeze Bypass", "Low temperature detection has been bypassed", "Zone"),
'ZH': ("Freeze Alarm Restore", "Alarm condition eliminated", "Zone"),
'ZJ': ("Freeze Trouble Restore", "Trouble condition eliminated", "Zone"),
'ZR': ("Freeze Restoral", "Alarm/trouble condition has been eliminated", "Zone"),
'ZS': ("Freeze Supervisory", "Unsafe freeze detection system condition", "Zone"),
'ZT': ("Freeze Trouble", "Zone disabled by fault", "Zone"),
'ZU': ("Freeze Unbypass", "Low temperature detection bypass removed", "Zone"),
}
def parse_record(self, data):
try:
rectype = data[0] & 0xc0
payloadlength = data[0] & 0x3f
payloadtype = data[1:2]
payload = data[2:2 + payloadlength]
nextrec = data[3 + payloadlength:]
except IndexError:
self.error('Record parse error')
return (b'', b'', b'')
# Verify check byte
checksum = 0xff ^ reduce(lambda x,y: x^y, data[:3 + payloadlength])
if checksum != 0:
self.error('Check byte error')
return (b'', b'', b'')
if rectype == 0xc0:
return (payloadtype, payload, nextrec)
else:
return (b'', b'', nextrec)
def __init__(self, client_ip, msg):
self.client_ip = client_ip
while msg:
(t, payload, msg) = self.parse_record(msg)
self.debug("%s" % (t + b' ' + payload))
if t == b'#':
self.account_number = payload.decode('ascii')
elif t == b'A':
self.extra_text = payload.decode('ascii')
elif t == b'N':
try:
area = int(payload[2:3])
event_code = payload[3:5].decode('ascii')
value = int(payload[5:8])
except:
self.error("Payload parse error")
continue
# Populate class properties
self.area = area
self.value = value
try:
(self.event, self.description, self.value_name) = self.EVENTS[event_code]
except KeyError:
self.error("Unknown event code " + event_code)
class TexecomService(socketserver.BaseRequestHandler):
error = lambda self, msg: logger.error(msg, extra={'tag': self.client_address[0]})
info = lambda self, msg: logger.info(msg, extra={'tag': self.client_address[0]})
debug = lambda self, msg: logger.debug(msg, extra={'tag': self.client_address[0]})
# POLL flags (not all of these are verified - see docs)
FLAG_LINE_FAILURE = 1
FLAG_AC_FAILURE = 2
FLAG_BATTERY_FAILURE = 4
FLAG_ARMED = 8
FLAG_ENGINEER = 16
def handle_poll(self, data):
self.debug("%s" % (data))
try:
parts = (data[4:].decode('ascii')).strip().split('#')
account = parts[0]
flags = ord(parts[1][0])
except:
self.error("POLL parse error")
return
self.info("Poll for a/c %s flags 0x%02x" % (account, flags))
# Check we recognise the account number and that
# the client IP matches
if self.server.account_manager.get_ip(account) != self.client_address[0]:
self.error("Invalid IP address for account %s" % (account))
return
# Send ack/polling delay in minutes
interval = self.server.account_manager.get_polling_interval(account)
self.request.send(b'[P]\x00' + bytes([interval]) + b'\x06\r\n')
# Record poll event
self.server.account_manager.polled(account)
# Post retained status update to broker
info = {
'client_ip': self.client_address[0],
'client_port': self.client_address[1],
'account': int(account),
'timestamp': datetime.now().isoformat(),
'interval': interval * 60,
'flags_raw': flags,
'line_failure': (flags & self.FLAG_LINE_FAILURE) > 0,
'ac_failure': (flags & self.FLAG_AC_FAILURE) > 0,
'battery_failure': (flags & self.FLAG_BATTERY_FAILURE) > 0,
'armed': (flags & self.FLAG_ARMED) > 0,
'engineer': (flags & self.FLAG_ENGINEER) > 0,
}
self.server.mqtt_client.publish("alarms/%s/status" % (account), json.dumps(info), qos=1, retain=True)
def handle_message(self, data, parser):
# Parse message
message = parser(self.client_address[0], data[1:])
self.info("%s: a/c %s area %d %s %s %d %s" % (type(message).__name__, message.account_number, message.area, message.event, message.value_name, message.value, message.extra_text))
if message.description:
self.debug(message.description)
# Check we recognise the account number and that
# the client IP matches
if self.server.account_manager.get_ip(message.account_number) != self.client_address[0]:
self.error("Invalid IP address for account %s" % (message.account_number))
return
# Send ACK
self.request.send(data[0:1] + b'\x06\r\n')
# Post event message to broker (not retained)
info = {
'client_ip': self.client_address[0],
'client_port': self.client_address[1],
'account': int(message.account_number),
'timestamp': datetime.now().isoformat(),
'area': message.area,
'event': message.event,
'value': message.value,
'value_type': message.value_name,
'extra_text': message.extra_text,
}
self.server.mqtt_client.publish("alarms/%s/event" % (message.account_number), json.dumps(info), qos=1, retain=False)
msg = "Area %d %s %s %d" % (message.area, message.event, message.value_name, message.value)
if message.extra_text:
msg = msg + " (" + message.extra_text + ")"
self.server.mqtt_client.publish("alarms/%s/message" % (message.account_number), msg, qos=1, retain=False)
def handle(self):
self.debug("Client connected from %s:%s" % (self.client_address[0], self.client_address[1]))
while True:
data = self.request.recv(1024)
if not data:
break
# Dump raw packet
self.debug('RAW: %s' % (hexlify(data)))
if data[0:3] == b'+++':
# End of transmission - we'll got a TCP disconnection after this
# so just ignore this silently
continue
# All other messages should have <CR><LF> terminator which we
# can remove
if data[-2:] != b'\r\n':
self.error("Ignoring line with missing terminator")
continue
data = data[:-2]
# Determine packet type and pass to handler
if data[0:4] == b'POLL':
# Polling packet
self.handle_poll(data)
elif data[0:1] == b'2':
self.handle_message(data, ContactId)
elif data[0:1] == b'3':
self.handle_message(data, SIA)
else:
self.error("Unhandled message: %s" % (hexlify(data)))
self.debug("Client disconnected")
self.request.close()
class ThreadedTCPServer(socketserver.ThreadingMixIn, socketserver.TCPServer):
pass
def on_mqtt_connect(client, userdata, rc):
logger.info("MQTT connection established: %d" % (rc), extra={'tag': ''})
def on_mqtt_disconnect(client, userdata, rc):
logger.info("MQTT connection lost: %d" % (rc), extra={'tag': ''})
def on_mqtt_publish(client, userdata, mid):
logger.debug("MQTT publish complete", extra={'tag': ''})
def main():
# Start account manager
manager = AccountManager()
# Start threaded MQTT client
MQTT_HOST = get_config('mqtt', 'host')
MQTT_PORT = int(get_config('mqtt', 'port'))
MQTT_USERNAME = get_config('mqtt', 'username')
MQTT_PASSWORD = get_config('mqtt', 'password')
MQTT_CAFILE = get_config('mqtt', 'cafile')
logger.info("Starting MQTT client for %s:%u" % (MQTT_HOST, MQTT_PORT), extra={'tag': ''})
client = mqtt.Client()
client.on_connect = on_mqtt_connect
client.on_disconnect = on_mqtt_disconnect
client.on_publish = on_mqtt_publish
if MQTT_CAFILE:
client.tls_set(MQTT_CAFILE)
if MQTT_USERNAME and MQTT_PASSWORD:
client.username_pw_set(MQTT_USERNAME, MQTT_PASSWORD)
client.connect_async(MQTT_HOST, MQTT_PORT, 60)
client.loop_start()
# Start ARC server
SERVER_HOST = get_config('server', 'host')
SERVER_PORT = int(get_config('server', 'port'))
logger.info("Starting alarm server on %s:%u" % (SERVER_HOST, SERVER_PORT), extra={'tag': ''})
# Start monitoring missed polls
manager.start_polling_watchdog()
manager.mqtt_client = client
t = ThreadedTCPServer((SERVER_HOST, SERVER_PORT), TexecomService)
t.mqtt_client = client
t.account_manager = manager
t.serve_forever()
if __name__ == '__main__':
if len(sys.argv)>1 and sys.argv[1] == '-d':
# Daemonize while retaining logger file handles
daemon = daemon.DaemonContext(
pidfile = lockfile.FileLock(PID_FILE),
files_preserve = [ fh.stream ],
)
logger.info("Daemonizing...", extra={'tag': ''})
daemon.open()
# Log exceptions
try:
main()
except Exception:
logger.exception("Terminated due to exception", extra={'tag': ''})