Document that some block parameters need to be coherent with the Simulink fixed time-step #165
Comments
In our normal workflow for the controllers we have built on top of wb-toolbox there is always a I am not sure how to make the state explicit while using our filter classes, that contain internally the information about previous state they need. Instead, for what concern the sample time, we should definitely try to read it directly from Simulink. This would require modifying the public APIs of |
Do you copy @FabioBergonti? Do you agree?
To be honest I really think that explicitly modelling discrete system is only viable way to achieve important features in the long term for our controllers/estimator, such the possibility to rollback in time (useful also for some RL algorithms) or to enable the use of variable step integrators for hybrid systems (hybrid in the sense that the controller is discrete, while the plan is continuous) . I think it may be doable to modify those classes to make sure that they expose an interface such as: size_t getInternalStateSize() const;
bool getInternalState(yarp::sig::Vector & stateBuffer) const;
bool setInternalState(yarp::sig::Vector & stateBuffer); but for anything related to ctrlLib we should before check with @pattacini .
To be honest, I would really like to avoid that, due to the following limitations:
|
If I understood what you mean, and I am not really sure, this:
considering the current status, is in contrast with this:
because even if the state was explicit, the output of the filter would be evaluated at the same rate of the simulation. Moreover, it is not clear to me how we should handle these classes that require a fixed step in a variable step scenario. Is what you propose related to have the possibility to run the filter at a higher frequency than the simulation's one? |
At the moment, it is not possible with the existing blockfactory/WB-Toolbox functionality to make the (discrete) state explicit, as there is no way to set or get the discrete state in the |
I was aware of that
Yes, I know the presence of Ts. I acted on it to modify the simulink frequency. I think my problems were more related to the frequency that simulink received the informations from gazebo |
Ok if we are talking about multirate S-Function blocks we are accessing an entire new world ;) |
|
Sorry, I just noticed that the link was pointing to the multi rate section of Simulink. You can specify the period of the discrete block even if it is a single rate block, sorry for the confusion. |
Ok, the right Simulik documentation is this: https://it.mathworks.com/help/simulink/sfg/sample-times-cpp.html. |
Exactly! |
Related to #165 (comment), as an example, a possible not optimized implementation of those three methods for the size_t Filter::getInternalStateSize() const
{
return ((m-1)+(n-1))*y.length();
}
bool getInternalState(yarp::sig::Vector & stateBuffer) const
{
size_t idx = 0;
stateBuffer.resize(this->getInternalStateSize());
for (size_t i=1; i<m; i++) {
for (size_t j=0; j<y.length(); j++) {
stateBuffer[idx] = uold[i-1][j];
idx++;
}
}
for (size_t i=1; i<n; i++) {
for (size_t j=0; j<y.length(); j++) {
stateBuffer[idx] = yold[i-1][j];
idx++;
}
}
return true;
}
bool setInternalState(const yarp::sig::Vector & stateBuffer)
{
size_t idx = 0;
if (stateBuffer.size() != this->getInternalStateSize())) {
return false;
}
for (size_t i=1; i<m; i++) {
for (size_t j=0; j<y.length(); j++) {
uold[i-1][j] = stateBuffer[idx];
idx++;
}
}
for (size_t i=1; i<n; i++) {
for (size_t j=0; j<y.length(); j++) {
yold[i-1][j] = stateBuffer[idx];
idx++;
}
}
return true;
} At least for retrieving, a similar method was already added in robotology/icub-main@295ced9 . |
Summary
Document that some block parameters need to be coherent with the Simulink fixed time-step.
In the
DiscreteFilter
andMinimumJerkTrajectoryGenerator
, the parametersTs
andSampleTime
respectively need to be coherent with the simulation timestep of the Simulink model.Note that this would not be necessary if this models would be represented as discrete systems with an explicit state, instead of instantaneous system with an hidden state whose evolution is triggered by an evaluation of the
output
function.cc @gabrielenava
Motivation
I remember that several users (in particular @FabioBergonti) were changing the simulation time-step of Simulink in some simulation, but I am not sure that they were aware of the need of changing the parameters of the
MinimumJerkTrajectoryGenerator
.The text was updated successfully, but these errors were encountered: