-
Notifications
You must be signed in to change notification settings - Fork 495
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
add timeout parameter to cli and driver #2586
base: master
Are you sure you want to change the base?
Conversation
9822961
to
c33a03a
Compare
c577c35
to
60f93aa
Compare
here is how to change timeout of the remote driver
without the timeout property
in case of CLI commands
|
commands/root.go
Outdated
timeoutDuration = defaultTimeoutCli | ||
} | ||
} | ||
flags.DurationVar(&options.timeout, "timeout", timeoutDuration, "Override the default global timeout (20 seconds)") |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
"(20 seconds)" not needed as already shown in default (and could be different in reality)
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Alternatively, this could take a value in seconds (assuming we don't expect users to specify timeouts in nano-seconds etc). I know we do so in some other places, for example "stop-timeout" on docker run
;
--stop-timeout int Timeout (in seconds) to stop a container
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
this takes a duration at the moment, let's say we want 70 seconds timeout, then we should set it as follows:
--timeout 1m10s
# or
--timeout 70s
# or
export BUILDX_TIMEOUT='70s'
if not set, we fallback to defaultTimeoutCli = 20 * time.Second
(20 seconds)
if we provide a timeout as an integer, for example:
--timeout 70
this throws an exception similar to this:
invalid argument "70" for "--timeout" flag: time: missing unit in duration "70"
is this okay? should we rely on timeout in seconds as an integer?
@@ -214,7 +214,7 @@ func (d *Driver) wait(ctx context.Context, l progress.SubLogger) error { | |||
select { | |||
case <-ctx.Done(): | |||
return ctx.Err() | |||
case <-time.After(time.Duration(try*120) * time.Millisecond): | |||
case <-time.After(d.Timeout / time.Microsecond): |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
time.Microsecond
in here does not really make logical sense. Use 1000 or / time.Second * time.Millisecond
.
I think this should probably also have some min/max values. Or maybe it doesn't make sense to make these dynamic at all. Some users might say don't fail and set timeout to very big number but that doesn't mean that they want retry mechanism to wait for a long time. Same for very small timeout.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
let's trace that, we assume that we start with try = 1
and have 15 attempts, the operation takes longer than expected
in the current implementation we have an incremental timeout in place, where with every new attempt we wait 120ms longer:
The calc #1 timeout is: 120ms
The calc #2 timeout is: 240ms
The calc #3 timeout is: 360ms
The calc #4 timeout is: 480ms
The calc #5 timeout is: 600ms
The calc #6 timeout is: 720ms
The calc #7 timeout is: 840ms
The calc #8 timeout is: 960ms
The calc #9 timeout is: 1.08s
The calc #10 timeout is: 1.2s
The calc #11 timeout is: 1.32s
The calc #12 timeout is: 1.44s
The calc #13 timeout is: 1.56s
The calc #14 timeout is: 1.68s
The calc #15 timeout is: 1.8s
This means we have a 14,4 seconds to complete an operation in this context.
In the logic I'd like to propose there's no incremental part, but it depends on the default timeout value, we assume that d.Timeout == (defaultDriverTimeout = 120 * time.Second)
, so that 15 * 120 = 1800
:
The calc #1 timeout is: 120ms
The calc #2 timeout is: 120ms
The calc #3 timeout is: 120ms
The calc #4 timeout is: 120ms
The calc #5 timeout is: 120ms
The calc #6 timeout is: 120ms
The calc #7 timeout is: 120ms
The calc #8 timeout is: 120ms
The calc #9 timeout is: 120ms
The calc #10 timeout is: 120ms
The calc #11 timeout is: 120ms
The calc #12 timeout is: 120ms
The calc #13 timeout is: 120ms
The calc #14 timeout is: 120ms
The calc #15 timeout is: 120ms
This means we have a 1,8 second window to complete an operation in this context, with the default timeout value set. By changing the default timeout value we can control how long every interval is, and every interval is equal.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
most probably it makes sense to control how many attempts we have rather than tailor the default timeout, or even leave it as is
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
^
966aaf3
to
7586654
Compare
@@ -38,6 +39,8 @@ type Node struct { | |||
Labels map[string]string | |||
} | |||
|
|||
const defaultDriverTimeout = 120 * time.Second |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
as such:
- CLI by default has 20 seconds timeout, it can be changed by a user by providing CLI option or env. variable
- buildx driver factory has 120 seconds timeout, it cannot be changed by a user, it's up to a buildx driver developer to define that value
timeoutChan := time.After(d.Timeout) | ||
ticker := time.NewTicker(d.Timeout / time.Microsecond) |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I'd like to propose quite similar logic here. With the default timeout of 120s we say that every 120ms we poll for replicas. Current behavior is to fail after 120s, with fixed 100ms intervals.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
What's your opinion? Should the default timeout value be coupled to retry intervals?
71b2c8f
to
1b49854
Compare
Signed-off-by: avoidik <[email protected]> Signed-off-by: Viacheslav Vasilyev <[email protected]>
Signed-off-by: Viacheslav Vasilyev <[email protected]>
Signed-off-by: Viacheslav Vasilyev <[email protected]>
Signed-off-by: Viacheslav Vasilyev <[email protected]>
Signed-off-by: Viacheslav Vasilyev <[email protected]>
Signed-off-by: Viacheslav Vasilyev <[email protected]>
Signed-off-by: Viacheslav Vasilyev <[email protected]>
5164820
to
752b04e
Compare
CLI timeout consistency info
Drivers timeout consistency info
|
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
m
hello,
this is an attempt to make timeout settings consistent
(please consider this contribution under any appropriate permissive and open-source friendly license)