Introduction

cnipol is a software package designed to acquire and analyze data from the Relativistic Heavy Ion Collider (RHIC) polarimeters at the Brookhaven National Lab (BNL). The first objective of this package is usually referred to as the "online" layer and designed to support the data acquisition and to provide a quick feedback by carrying out a fast online analysis. The second objective is to execute a more rigorous "offline" data analysis and present the results in a systematic way. It is normally referred to as the "offline" layer of cnipol.

There is a wiki page with some details about the RHIC polarimetry:

https://wiki.bnl.gov/rhicspin/Polarimetry

The entry page with links to results obtained with cnipol can be found at

http://www.phy.bnl.gov/cnipol/

General remarks

The code for the analysis of the RHIC polarimeters data has changed significantly starting 2010. Nevertheless, one may still find it useful to look through the older documentation which can be found at

http://www4.rcf.bnl.gov/~cnipol/Analysis/pC/index.html

How to configure and install cnipol

The best way to start with the analysis is to clone the latest version of the code from the git repository. From the location where the package will be installed on your machine (such as eic0005)issue the following command:

git clone https://github.com/rhicspin/cnipol.git
cd cnipol

If you plan to push changes back to the repository a github account is required. The source code in this case can be cloned via ssh protocol:

git clone [email protected]:rhicspin/cnipol.git
cd cnipol

The analysis framework depends on a few external libraries and programs including

  • ROOT
  • MySQL

The data acquisition and online processing code depends on CERNLIB and CDEV.

Before the code can be compiled and executed a number of environment variables must be set. We provide an example bash script script/setup.sh with predefined paths which should work on the eic cluster of the RACF (RHIC and ATLAS Computing Facility). Review and modify this script as needed to match your specific system configuration. An example is the variable CNIPOL_DIR, which the directory you setup the code. This script can be ran with an optional argument for the RHIC run number, e.g. run_id = 9|11|12|13|15|17, execute in the terminal (Note: You need to be bash shell. Type bash):

source script/setup.sh [run_id]

Once the environment variables are set the cnipol package can be built in $CNIPOL_DIR as:

mkdir build
cd build
cmake28 .. -DCMAKE_BUILD_TYPE=RelWithDebInfo
make

The compiled executables should appear in this build directory along with the cnipol libraries.

How to run cnipol

Make sure the following environment variables are set to valid locations before running the cnipol executables

$CNIPOL_DATA_DIR
$CNIPOL_RESULTS_DIR

asym accepts a number of options which can be listed by running it with a -h option. Here we just give a few most common examples used to process regular and calibration data.

To analyze a regular data file simply do in the build directory:

asym -r <meas_id>

where <meas_id> is a unique name of a measurement, e.g. 12345.001. Note that usually <file_name> = <meas_id>.data. The program searches for the input <file_name> file in $CNIPOL_DATA_DIR and creates an output directory <meas_id> in $CNIPOL_RESULTS_DIR. Typically, the output directory contains a ROOT file with a predefined set of histograms, a log file (stdoe.log) with the entire output of the program, a PHP file with information about the measurement and results to display on the web, and a file with calibration results.

To analyze an alpha or pulser measurement use the --alpha option:

asym --alpha -r <meas_id>

Batch processing multiple data files

Once in a while, when, for example, the cnipol code is modified one may need to re-analyze a large number of data files. This can be achieved in several ways by utilizing common linux tools. Here for completeness we provide a simple shell script that takes a text file containing a list of measurements (one <meas_id> per line) as a single argument and starts a certain number of parallel jobs in the background. The scripts for energy calibration and regular runs can be executed respectively as:

script/run_asym_alpha.sh <meas_list>
script/run_asym.sh <meas_list>

How to produce summary plots

Before you begin you should source the setup file as decribed above.

Often it is useful to see how polarization or other observables change from measurement to measurement during some period of time. To study such time dependence we developed masym, a program that runs on a set of measurements analyzed with asym. The output ROOT files produced by asym are used as input to masym. Executing the following command will create a <meas_list> directory in $CNIPOL_RESULTS_DIR with a ROOT file containing summary histograms:

masym -m <meas_list>

Here <meas_list> is a plain text file with a list of measurements to process. This file is assumed to exist in $CNIPOL_RESULTS_DIR/runXX/lists/ and to have one <meas_id> per line.

Optionally, the analyzer can provide a plain text file $CNIPOL_RESULTS_DIR/runXX/hjet_pol with H-Jet polarization values, and one file $CNIPOL_RESULTS_DIR/runXX/cdev_info/cdev_NNNNN per fill NNNNN containing intensity and other beam parameters. Information from these text files will be used by masym in the summary plots. Information from CDEV can be extracted using the following script on the acnlin CAD cluster:

$CNIPOL_DIR/script/get_fill_info.sh <NNNNN>

where must be replaced with an actual fill number.

Similarly to masym we provide a program to study time dependences in a set of alpha-calibration measurements. This program is called malpha and can be invoked as:

malpha -m <meas_list>

where <meas_list> is a file in $CNIPOL_RESULTS_DIR/runXX/lists/ with a list of unique names corresponding to measurements recorded by the polarimeters when no beam was present in the RHIC.

General Description of Directory Layout

There are 7 major directories in the cnipol package:

cnipol/inc/ -- This directory contains all the source code header files

cnipol/src/ -- This directory contains all the cpp files

cnipol/build/ -- This is build directory to compile the code using make

cnipol/webview/ -- This directory contains all the code relavent for the webpage

cnipol/script/ -- This directory contains all the scripts that can quickly allow a user to run the code

eicdata/eic0005/runXX/ -- This directory contains lists. The list of measuements, the list of target status, and the lists from cdev.

eicdata/eic0005/run17/ -- This directory holds all the data after processing through asym (Using 17 as an example, could be any other run number).

Automating the Process

First, you need to follow the link below to set up a tunnel to the blue and yellow pC machines at IP 12. This will provide you with a tunnel into the machines without requiring a password.

https://wiki.bnl.gov/rhicspin/Automated_pC_setup

The name of the script to execute is run_asym_daemon.sh. However, the first line in the script should be changed to the location of the setup.sh and the run number.

After the tunnel has been established you can start the automated process by executing the following command:

nohup ./run_asym_daemon.sh > some_output_file_name

and you can put an ampersand at the end of the process if you want to hide it. The ampersand will allow you to continue working in your current terminal. Regardless, the process will be running and looking for new files every 60 seconds.

Alpha Calibration File

During the course of the run, a long alpha measurment should occur and create the alpha calibration files needed for properly processing the measurments. Once this file is created you will need to edit the following code to include the file name of the alpha calibration. You can find the code at the following:

/contrib/RunPeriod.inc

Make sure to change the start_time, the polarimeter_id, the alpha_calib_run_name, and possibly the gain_slope (may not need to include the gain_slope at all). The other parameters are the default tdc and adc cuts on the bananas plots.

Other polarimetry software packages

Different people have been working on analysing polarimetry data. Some notable packages used for this purpose are:

ags_cni

Code for AGS data analysis.

AGS has a jet polarimeter much like the one at RHIC. Analysis code has branched a long time ago and is now supported by CAD.

hjet-analysis

Code for the H-jet polarimeter data analysis

Supported by the RHIC Spin group. As many other analyses it's reader code is based on the code found in rdatautil.c.

About

Proton beam polarization measurement with recoil p-Carbon polarimeters

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Contributors 3

  •  
  •  
  •